Guide · HS classification · Chapter 84 and 85 · Duty lines
One voltage figure can move a transformer from 5% import duty to 25%. A Vietnam HS code is read at 8 digits, so capacity and function set the rate, not the word “machine” on your invoice.
Written by our customs desk in Ho Chi Minh City. · Skip to the code table

Short answer: a Vietnam HS code has 8 digits. The first 6 follow the World Customs Organization’s HS system, and the last 2 come from the ASEAN nomenclature used in Vietnam’s list. Machinery mostly falls in Chapter 84 and electrical equipment in Chapter 85. Duty and policy are then read on that exact line.
This guide is for freight agents, EPC contractors and factory owners shipping equipment to Vietnam. Below are real duty lines for transformers, cranes and boilers, the 6 steps our customs desk follows, and 5 errors that cost importers money. It is working guidance, not a legal ruling. The importer of record still owns the code it declares.
Read a code from left to right, and each level narrows the goods. Here is one transformer line from the 2026 tariff file:
| Level | Code | What it means |
|---|---|---|
| Chapter | 85 | Electrical machinery and equipment |
| Heading | 85.04 | Electrical transformers, static converters and inductors |
| Subheading | 8504.22 | Liquid dielectric, above 650 kVA and up to 10,000 kVA |
| Vietnam line | 8504.22.93 | High side voltage of 66 kV or more, but less than 110 kV |
A seller’s 6-digit code stops one level too early. In this subheading, the last 2 digits change the most-favored-nation (MFN) duty from 5% to 25%.
Start with what the machine does, not how it is powered. An electric motor alone does not move a pump to Chapter 85. A pump driven by a motor still classifies as a pump, in heading 84.13.
Energy source can still decide the heading. An industrial furnace that runs on electricity belongs in 85.14, while a non-electric one goes to 84.17. That is why we ask for the data sheet before we name a code.

Transformers show how much the last digits matter. All rows below are liquid-dielectric transformers, such as oil-immersed units, and exclude step-voltage regulators. The rates come from our 2026 tariff file.
| Transformer | Vietnam HS code | MFN duty | Policy flag in the file |
|---|---|---|---|
| 400 kVA, 22 kV | 8504.21.99 | 5% | Energy efficiency and labeling |
| 5,000 kVA, 35 kV | 8504.22.99 | 15% | Energy efficiency and labeling |
| 5,000 kVA, 66 kV | 8504.22.93 | 25% | Energy efficiency and labeling |
| 10,000 kVA, 110 kV | 8504.22.92 | 5% | Energy efficiency and labeling |
| 12,000 kVA | 8504.23.10 | 5% | None shown |
| 40,000 kVA (40 MVA) | 8504.23.29 | 5% | None shown |
On a 5,000 kVA unit, moving from 35 kV to 66 kV adds 10 points of duty. At 110 kV the same unit drops back to 5%. A wrong voltage on the invoice is an expensive typing error.

A certificate of origin can change the picture. On line 8504.22.99 the file shows 0% under the Japan and EU agreements and 0% under Form E, with an exception for Thailand. Korea shows 5% and RCEP shows 7.5%.
Dry-type units leave this group. Those above 500 kVA go to 8504.34, where most lines show 10% and explosion-proof lines show 3%.
The rating is not hypothetical for us. In April 2024 we trucked a 40 MVA, 110 kV transformer about 1,900 km by road, from Cam Pha to Binh Tan substation in Vinh Long. That was a domestic road move from the factory, so no import code applied. See the route and skid plan in our power transformer transport guide.
Send the catalogue, nameplate photo, invoice description and origin. We reply with the likely HS lines, the duty on each and the policy flags within 2 working hours.
Use this as a starting point when you budget. Rates are MFN import duty from the ECUS 2026 tariff file dated 3 October 2026. Confirm your line against the actual specs before you file.
| Cargo | Code | MFN | What decides it, or what to watch |
|---|---|---|---|
| Excavator, 360° rotation | 8429.52.00 | 0% | Rotating superstructure. Used units face age limits. |
| Crawler bulldozer | 8429.11.00 | 0% | Track-laying type |
| Mobile crane on tires | 8426.41.00 | 0% | Certificate flagged before clearance |
| Crawler crane | 8426.49.00 | 0% | Certificate flagged after clearance, before market use |
| Crane lorry | 8705.10.00 | 3% | Chapter 87, with a certificate before clearance |
| Tower crane | 8426.20.00 | 0% | Often shipped in sections |
| Overhead crane on fixed supports | 8426.11.00 | 5% | Not the same line as gantry cranes (8426.19.30, 0%) |
| Watertube boiler above 45 t/h | 8402.11 | 0% | Steam output in t/h |
| Watertube boiler up to 45 t/h | 8402.12 | 5% | Steam output in t/h |
| Steam turbine above 40 MW | 8406.81.00 | 0% | Output in MW |
| Gas turbine above 5,000 kW | 8411.82.00 | 0% | Output in kW |
| Diesel generating set above 375 kVA | 8502.13 | 5% | Quality check flagged |
| Wind generating set | 8502.31 | 0% | Trade remedy flag on towers from China |
| Machining center | 8457.10 | 0% | Spindle power splits the line |
| Industrial robot | 8479.50.00 | 0% | Only if no more specific heading fits |
| Switchgear panel above 1,000 V | 8537.20 | 5% | Panels up to 1,000 V (8537.10) range from 0% to 15% |
| Steel tank, not for gas | 73.09 | 5% | Chapter 73, unless mechanical or thermal equipment makes it a machine |
| Large steel gas vessel | 7311.00.99 | 0% | Small cylinders on nearby lines show up to 20% |
| Wind tower | 7308.20.11, .19 | 3% | Anti-dumping duty if from China, see below |
VAT is separate. The general rate is 10%, with a temporary cut to 8% on many goods through 31 December 2026 under Resolution 204/2025/QH15. The file shows “8/10” on these lines, so check the rate that applies to your goods. Our machinery import guide covers how duty and VAT are budgeted.
This is the order our customs desk follows, in short form. Starting at step 5 skips the notes that can move your goods to another heading.
Two codes may still look possible. In that case we list both, with the duty on each, and settle it with the importer before anything is filed. Past declarations help, but another forwarder’s code is only a clue because it may have been wrong.
Project cargo rarely arrives as one piece, and this is where a Vietnam HS code gets argued. Four rules do most of the work:


Take a boiler like the one above. Boiler casings and other boiler parts show 0% (8402.90), and a heat exchange unit shows 3% (8419.50). A complete watertube boiler up to 45 t/h shows 5%.
Declaring a complete boiler crate by crate at the lower rates invites a challenge under rule 2(a). The right line depends on what the goods really are: a complete boiler or separate parts. Some boiler modules may also point to heading 84.04, auxiliary plant for boilers.
Timing matters too. Press reports on Circular 85 say goods in Chapters 84, 85 and 90 arriving in one shipment no longer need the registered list and deduction sheet. For a disassembled machine or machine set split across shipments, the list goes in before the first declaration is registered.

Duty is only half of what the code controls. The same 8 digits can trigger permits, inspections or an extra duty, and these can hold a machine at Cat Lai longer than the duty payment would.
Our customs clearance guide shows how these checks fit with the document list and green, yellow and red channels.
Ask for one when the machine is high value, two lines look possible and the duty gap is large. The 25% and 5% transformer lines above are a good example. The importer applies to Vietnam Customs before the goods ship, using Form 01/XDTMS/NVTHQ with technical documents, plus samples where relevant.
The same reply flags a second problem: the form stated one use and the technical documents another. Have the engineer check the description before you file. A ruling is only as useful as the specs behind it, so it will not protect goods that differ from what you described.
Our free HS code lookup covers 11,871 eight-digit codes. The interface is in Vietnamese, but each code also shows its English description, with duty, VAT and origin rates. Type 84 or 85 to browse a chapter.
Used-machine age limits by HS heading, proof customs need, duty and VAT.
Machinery import guide →Document checklist, inspection channels, timeline and fees for machinery.
Customs guide →Real 40 MVA and 110 kV moves: permits, night arrival and skidding.
Transformer transport →Lowbeds, road permits and route surveys after your cargo clears customs.
Heavy haulage →Send the catalogue, nameplate photo, invoice description, origin, L×W×H and weight. You get the likely lines, duty, policy flags and an all-in clearance and trucking cost within 2 working hours. Freight agents: see how we work with agents.
Tony Tuan, CEO: WhatsApp +84 909 411 668 · ceo@projectshipping.vn
Overseas Department: WhatsApp +84 909 411 668 · ceo@projectshipping.vn
Calling from Vietnam: 0909 411 668
Last updated: November 2026




© 2017 – 2026 Project Shipping. Design by Thiết kế Web DC